Apportioning factor jacket

Factor for apportioning the thermal capacitance of a cable jacket/oversheath

Symbol
$p_j$
Formulas
$\frac{1}{2\ln\left(\frac{D_e}{D_{ar}}\right)}-\frac{1}{\left(\frac{D_e}{D_{ar}}\right)^2-1}$