Effective length per unit lay length of twisted conductors

The fact that triplex or three core cables are twisted together leads to the possible need of a correction factor to take into account the longer length of the cores. This correction factor is the lay length factor as given in Cigre TB 880 Guidance Point 20.

A typical lay length factor is 1.01.

Symbol
$F_{lay,3c}$

Default
1.01

Formulae
$\sqrt{1+\left(\frac{\pi D_{lay,3c}}{L_{lay,3c}}\right)^2}$