Factor apportioning the sheath jacket

Factor for apportioning the thermal capacitance of the jacket around each core of multi-core subsea cables.

Symbol
$p_{shj}$
Formulae
$\frac{1}{2\ln\left(\frac{D_{shj}}{D_{sh}}\right)}-\frac{1}{\left(\frac{D_{shj}}{D_{sh}}\right)^2-1}$
Related