Cyclic loading with daily, weekly, and yearly load factors
Cyclic loading with daily, weekly, and yearly load factors

Posted on 2016-08-16
Using the Neher McGrath method for the calculation of the rating of buried cables under cyclic loading conditions allows for a daily, weekly, and yearly load factor in the same calculation.

Variation of spacing between sheath bonding points
Variation of spacing between sheath bonding points

Posted on 2016-07-03
For single-core cable circuits with sheaths solidly bonded at both ends and possibly at intermediate points, the circulating currents and the resulting losses increase as the spacing increases,...

Magnetic field (EMF) : phase splitting
Magnetic field (EMF) : phase splitting

Posted on 2016-06-26
Phase splitting can be used to drastically reduce the magnetic fields of buried power cables. Also, the conductor cross-section can be less than half because the current is only half per split...

Cigre Session 2016 in Paris
Cigre Session 2016 in Paris

Posted on 2016-06-06
Meet the Cableizer team at CIGRE session 2016 at the Palais des Congrès in Paris, France

Cyclic loading
Cyclic loading

Posted on 2016-06-06
For the calculation of the rating of buried cables under cyclic loading conditions two main methods are used: The method according to IEC 60853 and the Neher McGrath method. The following post...

Cableizer validation test suite 2016 Q1
Cableizer validation test suite 2016 Q1

Posted on 2016-03-19
Continuously validating Cableizer is a task we take serious. Our extensive test suite is a supportive tool to verify our calculations after modifications in the formulas or solver routine.

Magnetic fields (EMF)
Magnetic fields (EMF)

Posted on 2016-02-22
Cableizer calculates the magnetic fields of multiple systems with different frequencies and load-flow directions. The magnetic field strength is diagrammed as impressive and meaningful...

Cable conductor sizes
Cable conductor sizes

Posted on 2016-01-07
The full range of IEC and AWG conductor sizes and corresponding standard DC resistance values is supported.

Two-/Three-core cables
Two-/Three-core cables

Posted on 2015-12-18
Enhanced modelling of multi-core cables and redefined calculation of its screen/sheath losses and internal thermal resistances.

Cableizer validation test suite 2015 Q4
Cableizer validation test suite 2015 Q4

Posted on 2015-12-16
Continuously validating Cableizer is a task we take serious. Our extensive test suite is a supportive tool to verify our calculations after modifications in the formulas or solver routine.

Three-core cables belted or screened
Three-core cables belted or screened

Posted on 2015-12-14
Modelling and calculation of the internal thermal resistance and ampacity of 3-core belted cables and screened cables with fillers.

Armour losses and double-layer armour
Armour losses and double-layer armour

Posted on 2015-11-20
The IEC standard 60287-1-1 describes methods to calculate the armour loss factor but does so for one layer of armour only. Other ampacity calculation programs allow the user to model as well only...